Vaporless Manufacturing,Inc Leak Detectors Models 99/LD2000, 99/LD2200,99/LD3000



| 99/LD2000 |
| • Available for Gasoline, Diesel, Alcohols, Bio diesel, Aviation |
| • For any Pump |
| • Electronic Interface Available |
| • Longest length Pipeline System |
| • Largest Volume Pipeline System |
| • Integrated Check Valve / Pressure Relief |
| • Field Adjustable Leak Threshold |
| |
|
| 99/LD2200 |
| • Available for Gasoline, Diesel, Alcohols, Bio diesel, Aviation |
| • For any Pump |
| • Longest length Pipeline System |
| • Largest Volume Pipeline System |
| • Field Adjustable Leak Threshold |
| |
|
| 99/LD3000 3" |
| • Available for Gasoline, Diesel, Alcohols, Bio diesel, Aviation |
| • For any Pump |
| • Combined Rigid and Flexible Pipe System up to 502 Gallons |
| • Rigid Pipe only up to 406 Gallons |
| • Longest length Pipeline System |
| • Smallest Profile |
| • Integrated Check Valve / Pressure Relief |
| • Field Adjustable Leak Threshold |
Vaporless Manufacturing,Inc Leak Detector Testers Models LDT-890 and LDT-890AF

| • Factory Certification for Catastrophic Annual Testing and Troubleshooting |
| • LDT-890\AF for Alcohols, Bio diesel and some chemical applications |
| • Ensures regulatory compliance |
| • Performs 3 GPH @ 10 PSI |
| • Precision or Functional Test |
| • Performs System Diagnostics; trouble shooting |
| • Accurate Viscosity adjusted leak rate |
Vaporless Manufacturing,Inc Automatic Repressurization Module Model ARM-4073

| • Works with any 99/LD2000 or 99/LD3000 VMI Leak Detector |
| • LDT-890\AF for Alcohols, Bio diesel and some chemical applications |
| • All Submersible Pumps |
| • Compensates for fixed solenoid delays |
| • Automatic re pressurization at daily start up |
Vaporless Manufacturing,Inc Fuel Transfer Controllers Models AST-4010 and AST-4012

| • AST-4010 Single Tank or AST-4012 Dual Tank |
| • High Level Warning - Shut Down and Alarm |
| • High Level Alarm - SHut Down and Lockout |
| • No Hydraulic Hammer |
| • No Valve restrictions |
| • Regulator compliance - empty transfer hoses |
| • Controls motors up to 25 HP |
| • Alarm Circuit / Alarm Relays |
| • Enclosure meets or exceeds U.L. Class 1, Group D Hazardous Environment Criteria |
Vaporless Manufacturing,Inc Overfill Protection Valves Models OFP-2/1, OFP-2/2, OFP-3/1 and OFP-3/2




| • For Above Ground Storage Tanks |
| • Meets Uniform Fire Code |
| • Meets NFPA code 30A requirements for complete shutdown @ 98% fuel level |
| • Model 2\1: One 4" tank opening required. Shutdown Valve and Pilot Valve mount on a 4" x 2" male pipe thread bushing (provided). For use with 2" drop tube only |
| • Model 2\2: Requires two tank openings; one opening may be 2" or 3" and the second opening should be 4" (two 4" openings are acceptable). 4" pipe thread bushing provided. Requires a minimum of one 2" and one 4" opening |
| • MODEL 3\1: One six inch tank opening required, OFP Valve and Pilot Valve mount on 6" male pipe thread Bushing provided. For use with 3" drop tube only |
| • MODEL 3\2: Requires two tank bung's. Combinations of : 2 - 4" bung's or 1 - 3" bung and 1 - 4" bung. Consult factory for other combination or custom configurations. One 4" male NPT Bushing provided to install Pilot Valve and to vent OFP Valve. For use with 3" drop tube only | |